Adept AdeptSight Reference Guide Manual de usuario Pagina 281

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 579
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 280
InstanceOrderingReferenceY
VPARAMETER
532
Reference Y coordinate used to compute the distance when either of the hsDistanceImage or
hsDistanceWorld ordering modes are enabled using the InstanceOrdering property.
Syntax
MicroV+
VPARAMETER (sequence_id, tool_id, 532, index_id, object_id) = value
value = VPARAMETER (sequence_id, tool_id, 532, index_id, object_id)
V+
VPARAMETER (sequence_id, tool_id, 532, index_id, object_id) $ip = value
value = VPARAMETER ($ip, sequence_id, tool_id, 532, index_id, object_id)
Type
Double
Range
Not applicable.
Parameters
sequence_id Index of the vision sequence. The first sequence is 1.
tool_id Index of the tool in the vision sequence. The first tool is 1.
ID 532: the value used to reference this property.
index_id N/A
object_id N/A
$ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP
address format, for example: 192.168.1.120.
InstanceOrderingReferenceY
AdeptSight Reference Guide, v3.2.x, Updated: 5/8/2012