Adept AdeptSight Reference Guide Manual de usuario Pagina 336

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 579
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 335
MaximumInstanceCountEnabled
VPARAMETER
518
When MaximumInstanceCountEnabled is True, the search is limited to the number of instances set by
the MaximumInstanceCount property
Syntax
MicroV+
VPARAMETER (sequence_id, tool_id, 518, index_id, object_id) = value
value = VPARAMETER (sequence_id, tool_id, 518, index_id, object_id)
V+
VPARAMETER (sequence_id, tool_id, 518, index_id, object_id) $ip = value
value = VPARAMETER ($ip, sequence_id, tool_id, 518, index_id, object_id)
Type
Long
Range
Value Description
1 Search is limited to number of instances specified by MaximumInstanceCount.
0 Search is not limited to a set number of instances.
Parameters
sequence_id Index of the vision sequence. The first sequence is 1.
tool_id Index of the tool in the vision sequence. The first tool is 1.
ID 518: the value used to reference this property.
index_id N/A
object_id N/A
$ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP
address format, for example: 192.168.1.120.
MaximumInstanceCountEnabled
AdeptSight Reference Guide, v3.2.x, Updated: 5/8/2012
Page 336
Vista de pagina 335
1 2 ... 331 332 333 334 335 336 337 338 339 340 341 ... 578 579

Comentarios a estos manuales

Sin comentarios