ShowResultsGraphics
VPARAMETER
150
When enabled, vision results are displayed in the image display control. When disabled, vision results are
not displayed.
Syntax
Micro V+
VPARAMETER (sequence_id, tool_id, 150, index_id, object_id) = value
value = VPARAMETER (sequence_id, tool_id, 150, index_id, object_id)
V+
VPARAMETER (sequence_id, tool_id, 150, index_id, object_id) $ip = value
value = VPARAMETER ($ip, sequence_id, tool_id, 150, index_id, object_id)
Type
Boolean
Range
Value Description
1 Enabled: Vision results are displayed in the image display control.
0 Disabled: Vision results are not displayed.
Parameters
$ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP
address format, for example: 192.168.1.120.
sequence_id Index of the vision sequence. The first sequence is 1.
tool_id Index of the tool in the vision sequence. The first tool is 1.
ID 150: the value used to reference this property.
index_id N/A
object_id N/A
ShowResultsGraphics
AdeptSight Reference Guide, v3.2.x, Updated: 5/8/2012
Page 461